Murphy LM500/LM500-TF Series Lube Level Maintainers
The LM500 maintains oil level on any size engine. It also supports installations that require a three-wire, snap-action switch.
Test feature allows test of float and switch
Direct mount capable
Eliminates under/overfill due to human error
See oil level and condition without shutting down
Simple installation
Automatically maintains lube level
Positive sealing thumb valve
The LM500’s form C (three-wire) contact allows a controller/annunciator to be wired as a closed loop system, resulting in a reliable fault-sensitive circuit. Refer to LM500 Series Flow Rate Chart for application data.
The FW Murphy LM500-TF Oil Level Maintainer includes a test feature that confirms both the float and switch are operating correctly with a single press of the test button. The LM500 series maintains the crankcase oil level of an engine, pump or compressor. Adjusted to the correct running oil level, it will replenish oil as it is used. The low-level switch will alarm and/or shut down the equipment, if supply oil is lost and the equipment continues to use oil.
As crankcase oil level drops, the LM500 float also drops and opens the thumb valve. This allows oil to flow from the supply tank through the LM500 and into the crankcase. When proper level is achieved in the crankcase, the LM500 float rises causing the thumb valve to close off further oil flow.
The simple and unique thumb valve is non-clogging and provides a positive, leak-free seal.
If the clean oil supply is depleted and oil level continues to fall, the low-level switch will operate an alarm or equipment shutdown.
Crankcase Balance Vent Connection: 1/2 NPTF (top)
Inlet Connection: 1/2 NPTF removable screen (side)
Outlet Connection: One connected, two not used (plugged)
2 x 3/4 NPTF (side)
1 x 3/4 NPTF (bottom)
Thumb Valve Material: Viton
Snap-switch: SPDT rating 10 A, 125 VAC; 0.5 A, 125 VDC; 10 A, 30 VDC
Wire leads: 18 AWG x 14 in. ± 2 in. (355 mm) length
Conduit Connection: 1/2 inch conduit (female, top)
Case: Die cast aluminum
Lens: Clear frog eye non-staining, high impact, high temperature polycarbonate; UV and heat stabilized
Dial: High visibility white background with solid green band for normal level indication
Maximum Inlet Pressure: 9.50 psi/25 ft. oil (head pressure)
Maximum Case Pressure: 15 psi (103 kPa)
Maximum Differential: 2 in. (51 mm) between running and stopped
Maximum Ambient Temperature: 250°F (121°C)
Float: 304 Stainless Steel
Flow Rates: Refer to LM500 Series Flow Rates chart for application data
Dimensions: Overall 6-9/16 inch tall x 6-3/16 inch wide x 3-1/2 inch deep
For exact dimensions, refer to document 00-02-0729 LM500 Installation InstructionsLM500/LM500-TF Shipping Dimensions: 9.5 (W) x 7.5 (D) x 11 in. (H) (241.3 (W) x 190 (D) x 279.4 mm (H))
LM500/LM500-TF Shipping Weight: 3 lbs. 7 oz (1.57 kg)