JUMO TYA 201 Single-phase thyristor power controller
Technical parameters
Load type: resistive and inductive loads, nominal inductance under transformer load does not exceed 1.2 Tesla (1.45T when power supply is overvoltage).
Load voltage: supports 400V, 460V, 500V.
Load current: provides a variety of current specifications (such as 20A, 32A, 50A, 100A, 150A, 200A, 250A).
Working mode:
Phase-shift trigger mode: supports 0-180° phase angle adjustment to achieve soft start function and avoid impact current.
Pulse trigger mode: cuts off the phase angle of the first half wave, suitable for transformer load control.
Control mode: supports secondary control modes such as U (voltage), U², I (current), I², P (power).
Operation mode:
Plain text display: equipped with plain text display, based on device parameter setting and status monitoring.
USB power supply and settings: supports power supply through USB interface, and can be set without external power supply.
Communication interface: RS422/485 or PROFIBUS-DP, support communication with host computer.
Product Features
Dual energy management system: optimize grid power and reduce energy consumption.
Soft start function: reduce the impact on the load through soft start with starting current limit.
Teaching function: can detect partial load disconnection and improve system reliability.
Diagnostic system: built-in diagnostic functions such as rotating magnetic field detection, including maintenance.
MoSi2 type heating element protection: monitoring and protection functions for specific heating elements.
Structure and configuration
Control element:
Microcomputer chip display: realize precise control and parameters.
Anti-parallel switch thyristor: two to ensure reliable on and off.
Seven: effective evaporation and extended equipment life.
Installation method:
Current ≤100A: can use 35mm side wall installation or back plate interchangeable installation.
Product advantages
Convenient operation:
Easy operation and setting through LCD display and 4 buttons.
USB interface and setting program, can be set without external power support.
Flexible control:
Supports phase-shift trigger mode and pulse trigger mode.
Secondary control methods include U, U², I, I² and P control.
Reliability and stability:
Built-in diagnostic systems (such as rotating magnetic field detection) ensure reliable operation of the equipment.
Monitoring and protection of MoSi2 heating elements.
Energy saving optimization:
Optimize grid power through dual energy management system.
Complies with VDE 0160 5.5.1.3 (5/88) and VDE 0106 part 100 (3/83) standards.